TPP2-F/TPP2-C
Surface probe pocket thermometers with flatsurface
contact
Fahrenheit and Celsiusversions
0.1 .F / 0.1 .C resolution
Easy-to-read digital display
Data hold to freeze display
Long battery life, 200 hours typical
Temperature ranges-50 .F to 480 .F (-50 .C to 250 .C) |
TPP1-F/TPP1-C
Same features as TPP2 but with an immersionprobe tip
Protective probe sleevewith pocket clip
TM-SW
Optional RS232 cable and software for TMA10 and TMD90
Record two channelssimultaneously T1 and T2 with TMD90 Air flow and
tempera-ture with TMA10
Store results for further |
TMD90
Dual input digital thermometer with triple display
High accuracy, multiple type input thermometer
Ideal for HVAC/R technicians, electricians, research, industrialprocess,
quality control
Dual inputs for easy super-heat and sub-cool temperaturemeasurements
Dual channel real time data acquisition with RS232 outputwith optional
software and cable, Model TM-SW
Triple display of T1, T2, T1 T2, and relative time stamp
Backlight
Deluxe hard carrying case, two Type K probes
Thermocouple |
Temperature
Ranges |
Accuracy |
Type K |
200 .C to 1370 .C
(328 .F to 2498 .F) |
0.1 % rdg + 0.7 .C
(0.1 % rdg + 1.4 .F) |
Type J |
-200 .C to 760 .C
(-328 .F to 1400 .F) |
0.1 % rdg + 0.7 .C
(0.1 % rdg + 1.4 .F) |
Type T |
-200 .C to 390 .C
(-328 .F to 730 .F) |
0.1 % rdg + 0.7 .C
(0.1 % rdg + 1.4 .F) |
Type R and S |
0 .C to 1760 .C
(32 .F to 3200 .F) |
0.1 % rdg + 0.7 .C
(0.1 % rdg + 1.4 .F) |
Type E |
-200 .C to 736 .C
(-328 .F to 1832 .F) |
0.1 % rdg + 0.7 .C
(0.1 % rdg + 1.4 .F) |
TMA10
Anemometer with flexible precision vane
Measure air velocity FPM or air volume CFM
Input surface area for accurate air flow measurements
Flexible vane sensor
Precise Thermistor for temperature measurements
Continuous moving average results for up to 2 hours
MIN/MAX/AVG readings
Air velocity average for multiple point
Data hold to freeze measurement display of both readings
RS232 interface output with optional software and cable,Model
TM-SW
Deluxe hard carrying case
Measurement |
Range |
Resolution
Accuracy |
Air Velocity |
0.40 to 25.00 m/s |
0.01 m/s. 2 % of full scale |
Air Flow |
125 to 4900 ft/min |
1 ft/min. 2 % of full scale |
Air Flow |
0.01 to 99.99 m3 /sec 0.01Area:
0 to 9.999 m |
.2 % of full scale |
Air Flow |
1 to 9999 ft3 /min Area:
0 to 9.999 ft |
1.0. 2 % of full scale |
Air Temperature 0 .C to 50 .C C (.F) |
(32 .F to 122 .F) |
0.1 .C/(.F) . 0.8 .C (1.5
.F) |
TRH22
Relative humidity and temperature meter
Relative function monitors humidity and temperature changes
Large dual display of RH and temperature
Complete with carrying case, battery and wet bulb chart
Min/Max/Data Hold
Measurement |
Ranges |
Accuracy |
Resolution |
Relative Humidity |
0 to 100 % |
5 % RH to 95 % RH 3 % RH |
0.1 %RH |
Ambient Temperature |
-20 .C to 60 .C (-4 .F
to 140 .F) |
0.8 .C (.1.6 .F) |
0.1 .C/0.1 .F |
|
|
|